| 1 | Electrical Panel Grounding Kit | Connects panel enclosures and grounding conductors to the protective earthing system. | Ground bar, bonding screws, lugs, washers, conductor, and mounting hardware. | Distribution boards, control panels, switchboards, and electrical cabinets. | Bare or insulated copper; aluminum may be used where permitted by the installation design. | IEC 60364; NFPA 70; local electrical codes. | Provides a low-impedance fault path so protective devices can disconnect power during an insulation fault. |
| 2 | Cable Tray Bonding Kit | Maintains electrical continuity across cable tray sections, joints, and accessories. | Bonding jumpers, two-hole lugs, serrated washers, bolts, and corrosion-resistant fasteners. | Metallic cable trays, ladders, bends, tees, and expansion joints. | Tinned copper or copper bonding braid. | IEC 61537; NEMA VE 1; NFPA 70. | Bridges joints that may have high contact resistance and keeps the tray system at a similar electrical potential. |
| 3 | Cable Gland Grounding Kit | Bonds armored or screened cables to an equipment enclosure. | Earth tag, locknut, gland components, serrated washer, and grounding conductor. | Motor control centers, junction boxes, switchgear, and industrial enclosures. | Copper braid, tinned copper wire, or a metallic cable armor path. | IEC 62444; IEC 60364; enclosure manufacturer instructions. | Transfers fault current from the cable armor or screen into the enclosure grounding network. |
| 4 | Motor Grounding Kit | Grounds motor frames and provides bonding between the motor, cable, and supply equipment. | Frame grounding lug, bonding conductor, cable gland parts, and terminal hardware. | Low-voltage motors, pumps, fans, compressors, and industrial drive systems. | Copper or tinned copper conductor sized according to the fault-protection design. | IEC 60034; IEC 60364; NFPA 70. | Keeps exposed conductive parts near earth potential and helps clear motor winding-to-frame faults. |
| 5 | Transformer Grounding Kit | Grounds the transformer tank and, where required, the neutral point of the winding. | Tank bonding conductor, neutral grounding connection, lugs, clamps, and hardware. | Distribution transformers, dry-type transformers, and transformer substations. | Copper, aluminum, or galvanized steel, selected for the system and environment. | IEC 60076; IEEE 80; IEC 60364. | Provides a controlled path for tank faults and establishes the intended reference for the transformer neutral. |
| 6 | Busbar Grounding Kit | Connects a grounding busbar to the main earthing terminal or grounding electrode system. | Copper bar, compression lugs, bonding links, supports, and identification labels. | Electrical rooms, data centers, substations, and industrial control rooms. | Bare copper or tinned copper bar and conductors. | IEC 60364; IEC 61439; local grounding regulations. | Creates a common connection point for protective conductors and equipment bonding conductors. |
| 7 | Telecommunications Grounding Kit | Reduces touch-voltage risk and provides bonding for communication equipment and racks. | Rack bonding conductor, grounding bar, lugs, rack bonding hardware, and labels. | Server racks, network cabinets, telecom rooms, and equipment shelters. | Insulated copper conductor, copper braid, or tinned copper bonding strip. | TIA-607; IEC 60364; local telecommunications grounding requirements. | Equalizes the potential of racks and metallic pathways while providing a route for fault and surge currents. |
| 8 | Solar PV Grounding Kit | Bonds photovoltaic module frames, mounting rails, and inverter equipment. | Module bonding clips, grounding lugs, rail bonding jumpers, cable, and clamps. | Rooftop arrays, ground-mounted PV systems, combiner boxes, and inverters. | Copper or tinned copper; compatible aluminum bonding parts may also be used. | IEC 62548; IEC 60364-7-712; NFPA 70. | Maintains continuity across metal module frames and mounting structures and helps conduct fault or lightning-related current safely. |
| 9 | Lightning Protection Grounding Kit | Connects air terminals and down conductors to the earth-termination system. | Earth clamps, test joints, down-conductor clamps, bonding conductors, and earth electrodes. | Buildings, warehouses, towers, industrial plants, and rooftop structures. | Copper, aluminum, or hot-dip galvanized steel, subject to compatibility requirements. | IEC 62305; NFPA 780. | Directs lightning current through designated down conductors and electrodes while limiting dangerous voltage differences. |
| 10 | Grounding Electrode Connection Kit | Connects grounding conductors to rods, tapes, grids, plates, or foundation electrodes. | Ground clamps, irreversible compression connectors, exothermic weld materials, lugs, and inspection points. | Building foundations, substations, utility sites, industrial plants, and grounding grids. | Copper, copper-clad steel, stainless steel, or galvanized steel, depending on the electrode system. | IEC 60364; IEEE 80; IEC 62561. | Transfers fault, surge, and lightning current into the soil through a mechanically secure and electrically continuous connection. |