| 1 | Confirm the core material and aging behavior | Identify whether the core is PIR, PUR, EPS, XPS, or mineral wool. Confirm density, closed-cell structure where applicable, moisture resistance, and the method used to determine long-term thermal performance. | The declared thermal conductivity should state the test temperature, specimen condition, thickness, and whether the value is initial or aged. Thermal performance should not be described as permanently unchanged without test evidence. | Technical data sheet; density test results; thermal-conductivity report using ASTM C177, ASTM C518, or EN 12667; documented aging or declared-value method. | Only an “R-value” is provided with no test method, thickness, temperature, or aging information. |
| 2 | Check dimensional accuracy and panel construction | Inspect panel thickness, width, length, squareness, flatness, joint geometry, adhesive coverage, and the alignment between the metal facings and foam core. | Measured dimensions should remain within the tolerances stated in the applicable product standard and purchase specification. Joints should close consistently without excessive gaps or crushing. | Incoming inspection records; calibrated measuring-tool certificates; cross-section samples; production drawings; dimensional inspection plan. | Variable thickness, visible core voids, uneven edges, delamination, or inconsistent joint engagement. |
| 3 | Verify mechanical strength for the intended span | Review panel load tables for span, support spacing, wind pressure, snow load, temperature effects, fastener layout, and serviceability limits such as deflection. | Load capacities should be based on tested or engineered panel assemblies, not foam compressive strength alone. Relevant testing may include ASTM C393 for sandwich flexural properties or EN 14509 for self-supporting metal-faced panels. | Third-party test report; structural calculations; load-span tables; design assumptions; fastener and support details; declared safety factors. | A single unsupported load value is advertised without span, support, deflection, temperature, or safety-factor information. |
| 4 | Review fire performance and regulatory compliance | Confirm the complete panel assembly’s reaction-to-fire, fire-resistance, smoke, and flame-spread performance for the project jurisdiction. | Fire classification must identify the exact core, facings, joint design, thickness, and test configuration. EN 13501-1 and ASTM E84 address different classification systems and should not be treated as interchangeable. | Current fire-test report; classification certificate; product-composition statement; installation limitations; evidence for the exact panel thickness and joint detail. | “Fireproof” wording without a classification, test standard, specimen description, or validity date. |
| 5 | Evaluate moisture resistance and corrosion protection | Check water absorption, vapor exposure, drainage, cut-edge protection, coating type, metal thickness, and compatibility with the building environment. | Water-absorption data should identify the test method, such as ASTM C272 for sandwich construction or the applicable foam-material method. Coating and metal specifications should be stated in measurable units. | Coating certificate; metal-facings specification; salt-spray or corrosion test where required; water-absorption report; installation and sealing instructions. | Unsealed cut edges, exposed foam, coating damage, trapped water at joints, or no guidance for humid or coastal conditions. |
| 6 | Assess manufacturing process control | Review incoming-material control, foaming or lamination parameters, adhesive application, curing time, batch traceability, calibration, and final inspection procedures. | A documented quality-management system, such as ISO 9001, should be supported by traceable batch records and corrective-action procedures. Certification alone does not prove every panel meets the project specification. | Valid management-system certificate; factory quality manual; inspection and test plan; batch identification; nonconformance and corrective-action records. | No batch number, no retained samples, undocumented process changes, or refusal to provide independent audit information. |
| 7 | Measure technical support and after-sales capability | Confirm design assistance, shop-drawing review, installation training, response times, replacement-panel policy, spare accessories, warranty terms, and complaint handling. | Support commitments should be written, including response time, warranty exclusions, storage conditions, repair procedures, and responsibility for design or installation errors. | Installation manual; approved shop drawings; project references without confidential client information; warranty document; service-level contact process; spare-part availability statement. | Verbal warranty promises, unclear exclusions, no installation guidance, or support limited to sales communication. |