| Portable FTIR Analyzer | 4,000–650 cm−1 | 4–8 cm−1 | DTGS or compact thermoelectrically cooled detector | ATR, diffuse reflectance, external fiber or contact interface | Approximately 1–30 scans per second, configuration dependent | About 25–40 × 20–35 × 10–20 cm | Field identification, incoming-material checks, plastics, powders and surface screening |
| Routine Benchtop FTIR with ATR | 4,000–400 cm−1 | 4 cm−1; commonly selectable to 2 cm−1 | DTGS or equivalent pyroelectric detector | Single- or multi-reflection diamond, germanium or zinc selenide ATR; transmission accessories | Approximately 2–20 scans per second | About 45–55 × 35–45 × 20–30 cm | Routine identification, quality control, polymers, pharmaceuticals and organic chemicals |
| Research-Grade Benchtop FTIR | 7,800–350 cm−1, depending on optical configuration | 0.5–4 cm−1 | DTGS, MCT or additional cooled detectors | ATR, transmission, diffuse reflectance, specular reflectance and gas cells | Up to approximately 20–100 scans per second at moderate resolution | About 55–70 × 45–60 × 25–35 cm | Advanced materials research, kinetics, gas analysis, thin films and quantitative spectroscopy |
| FTIR with Microscope Interface | 4,000–650 cm−1; extended ranges may be available | 2–8 cm−1 | MCT or DTGS, selected according to sensitivity and range | Micro-ATR, transmission, reflection and mapping accessories | Typically 1–10 spectra per second; mapping speed varies by sample and resolution | About 70–100 × 50–70 × 45–70 cm including microscope | Microparticles, inclusions, contamination analysis, forensic samples and failure investigation |
| Gas-Phase FTIR System | 4,000–400 cm−1; path and cell materials affect the usable range | 0.5–4 cm−1 | DTGS or MCT for improved detection of low-concentration species | Heated gas cell, long-path cell, flow-through cell and gas sampling manifold | Approximately 1–20 scans per second | About 55–80 × 45–65 × 25–40 cm, excluding external gas accessories | Emission monitoring, reaction studies, combustion gases and atmospheric research |
| Automated FTIR Process Analyzer | 4,000–400 cm−1, process-accessory dependent | 2–8 cm−1 | DTGS or MCT with temperature-controlled detector housing | Flow cell, fiber-optic interface, ATR probe or multipoint sampling system | Typical measurement cycle of 1–60 seconds, depending on sampling and averaging | About 60–100 × 50–80 × 30–60 cm, excluding control cabinets | Continuous process monitoring, blending control, reaction tracking and raw-material verification |